The smallest measurement range is 0 to 10 mbar, the largest 0 to 600 bar. The medium may be aggressive or viscous. All sensors can be used for static or dynamic measurings and work either with a piezoresistive element or a ceramic cell. The housing and the pressure ports are made of aluminum, stainless steel or plastic, depending on the medium. Accuracy of ±0,1 up to ±1%FSO is available, depending on the model and the measurement range. The supply of 12 to 36 VDC and the various output signals of 0/4…20 mA respectively 0…1/5/6/ or 10 VDC meet today’s industrial standards. Flexibility is guaranteed by various version of standardized mechanical and electrical connectors. All sensors made of stainless steel are available according to EEx ia llc T4.